TW-52I-HP
TW-52I-HP represents an evolution of your predecessor, TW-52-HP. Using additive manufacture, the sample flow chamber was redesigned inside the IP-67 cabinet. This generates space economy and offers greater protection for the sensors. It has an amperometric methodology and does not use reagents. Measures up to 20 ppm of free chlorine and allows transmission of both chlorine and pH values.
Downloads
ANALYZER
Measurement principle
Amperometric
Free chlorine range
0 to 20 ppm
Applicable pH range
5 to 8.5 pH
TRANSMITTER
Analog output
2 x 4 to 20 mA
Digital output
RS485 with Modbus protocol
CONTROLLER
ON-OFF/PWM
2 x NA (1A/250 Vca)
PID
2 x 4 to 20 mA
GENERAL
Indication
Graphic display
Power supply
90 to 240 Vca - 4-wire (50/60 Hz)
Case material
ABS V0
Ingress protection
IP-67
Dimensions
391 x 286 x 210 mm (WHD)
Total weight
4.2 kg