"PAINEL-COTACAO.PREENCHA-CAMPOS" | translate }}
OK
Add to Quote
0
Quotations
Quotation
days

No product found

Logotipo DigimedLogotipo Digimed
    • Analytical Instrumentation
      Environmental Analysis
      |Empresa
    • Products
      • Parameters
      • Categories
      • Systems
      • pH
      • Conductivity
      • Color
      • Turbidity
      • DO
      • Chlorine

      • Aluminum
      • Ammonia
      • Calcium
      • Chloride
      • Chromium
      • Coagulant
      • COD
      • Concentration
      • Copper
      • DO
      • Fluoride
      • Hardness
      • Iron
      • ISE
      • Lithium
      • Manganese
      • Methanol
      • Na,K,Li,Ca
      • Opacity
      • ORP
      • Ortophosphate
      • Potassium
      • Resistivity
      • Salinity
      • Silica
      • Sodium
      • Sulfate
      • Temperature
      • Total Suspended Solids-TSS
      • Zinc

      pH is defined as the hydrogenic potential of a solution and is determined by the concentration of hydrogen ions (H+), which characterizes it as acidic, neutral or alkaline. The knowledge of the pH allows the understanding of the behavior of chemical reactions, because their variation can favor oxidative processes, alter the balance of reactions and generate ideal conditions for other reactions to happen. In addition, we can evaluate the quality of food, cosmetics, beverages, among others. Therefore, pH is the most monitored and controlled chemical parameter in industrial processes. Count on Digimed to meet the most diverse pH applications with total commitment and excellence.

      imagem referente ao parâmetro

      Os sistemas são projetados com a melhor instrumentação disponível, e em conformidade com as normas nacionais e internacionais vigentes para manter a integridade do seu circuito de forma confiável e segura em todos os momentos. Como resultado, você economiza em custos de manutenção, minimiza o tempo de inatividade e prolonga a vida operacional. Clique aqui e saiba mais.

      Sistemas
    • Services
      • Technical Services
      • Calibration
    • Applications
      • Caldeiras
      • ETA - Estações de Tratamento de Água
      • ETE - Estação de Tratamento de Efluentes
    • Support
      • Downloads
      • Contact
      • Blog
      • Events
      • Site tutorials
      • Work with us
    • Services

    • Contact
    • Support
      • Downloads
      • Contact
      • Blog
      • Events
      • Site tutorials
      • Work with us
Botão DigiStoreBotão DigiStore
Login Without Password I forgot my passwordSign-up
Português English Español
Imagem Header

Turbidímetro para água bruta com Auto Limpeza | TB-44A-AL

Home
Product
TB-44A-AL
Imagem do produto

TB-44A-AL

Selo  CE

Focusing on medium and high turbidity readings, the TB-44A turbidity meter uses the reflectance method, protecting the optical bank and ensuring greater durability of the sensor unit, which works between 0 and 1000 NTU or 10,000 NTU.

From ETA, ETE and other complex chemical processes with explosive atmospheres (Exi) the TB-44A provides the safety and reliability needed in turbidity analysis in processes (online).

This version has a self-cleaning feature, specially designed to prevent solid particles from accumulating inside the sensor unit.

Trust your reading in a weatherproof and corrosion resistant (IP-67) die-cast aluminum (SAE-323) enclosure.

Application

  • General

ANALYZER

Measurement principle
Nefelométrico
Turbidty range
0 a 10.000 NTU

TRANSMITTER

Analog output
4 a 20 mA
Digital output
RS485 com protocolo Modbus

CONTROLLER

ON-OFF/PWM
2 x NA (1A/250 Vca)
PID
4 a 20 mA

GENERAL

Indication
Display alfanumérico de 2 linhas x 16 caracteres
Power supply
90 a 240 Vca - 4 fios (50/60 Hz)
Case material
Alumínio fundido SAE 323 (base) e plástico ABS (tampa frontal)
Ingress protection
IP-67
Eletronic unit dimensions
145 x 145 x 70 mm (LAP)
Bubble trap dimensions
160 x 590 x 160 mm (LAP)
Total weight
13 kg
Price upon requestFor more information, request a quote.
Quantity
Add to Quote

News and Updates

Managing Turbidity Spikes in Intake: Strategies for WTP Stability

29/01/2026

Discover Digimed's process instruments designed to manage turbidity spikes in raw water intake.

News image

Analytical Instrumentation for Dam Monitoring and the Impact on Environmental Compliance

News image

Environmental Compliance: The Role of the Opacimeter in Atmospheric Pollutant Management

News image

How Analytical Instrumentation Contributes to Managing the Water Crisis

News image

COP30: What to Expect from the Conference of the Parties in Brazil

News image

Fenasan: Digimed highlights instrument platform, digital transformation and environmental protection

News image

Complete guide to pH analysis: methodology, instruments and electrodes

News image

Why can field and process turbidity analysis be different?

News image

Why we should not control the dose of coagulants through Turbidity?

News image

Turbidity Analysis Technique

See all news
Logotipo Digimed

Digimed

  • Sitemap
  • About Us
  • Courses and Webinars
  • News and Blog
  • Certificates and Accreditations
  • Privacy Policy
  • Quality Policy

Products

  • pH
  • Conductivity
  • Color
  • Turbidity
  • DO
  • Chlorine

Services

  • Calibration
  • Technical Service

NEWSLETTER

Sign up to receive our newsletter with news and events.


Contact

+55 (11) 5633-2200

digimed@digimed.ind.br

Technical Service

  • at@digimed.ind.br

Address

Rua Marianos, 227 - Vila Gea - São Paulo/SP – CEP 04691-110

International

  • internacional@digimed.ind.br

Office hours

Monday to Thursday from 8:00 a.m. to 4:45 p.m. Friday and national holiday eve from 8:00 a.m. to 3:30 p.m. (Brasília Time)

Google Safe BrowsingConexão CriptografadaPagamento Seguro
DIGICROM ANALITICA LTDA - CNPJ 60.160.546/0001-31
Aplicação:
Produto Adicionado ao Carrinho Turbidímetro para água bruta com Auto Limpeza
Continuar Comprando