Conductivity Analyzers

Conductivity, Resistivity, Salinity and others

The online conductivity analyzers attend perfectily with different measure parameters such as conductivity, resistivity, salinity, concentration, cationic conductivity and diesel.

Solve the most difficult analysis challenges, reduce installations costs, maintenance, bring efficiency in the quality control. We are constantly innovating to ensure the satisfaction of our customers.

Questions about how the online conductivity meter works? Contact our experts or come and visit us and take part in one of our conductivity training sessions.

See all models in the table below and click to compare or view the characteristics of your preferred conductivity meter.

Compare the Models
Swipe to see more information Ok, I got it
Description Measurement Parameter Conductivity Range Power supply Installation Classification Area Conformity Analog Output Discrete Output Control Action
Conductivity Analyzer / Transmittter / Controller Conductivity / Resistivity / Salinity 0.001 µS/cm to 2 S/cm 90 to 240 Vac / 50 - 60 Hz (4 Wires) Panel, 2" Tube or Flat Surface - 1 x 4 to 20 mA 2 contacts NO (1A/250 Vac) Alarm / ON-OFF / PWM
Conductivity Analyzer / Transmitter / Controller Conductivity / Resistivity / Salinity 0.001 µS/cm to 2 S/cm 90 to 240 Vac / 50 - 60 Hz (4 Wires) 2" Tube or Flat Surface Ex db ia IIC T6 Gb (optional) 1 x 4 to 20 mA 2 contacts NO (1A/250 Vac) Alarm / ON-OFF / PWM
24Vdc Conductivity Analyzer/Transmitter/Controller Conductivity / Resistivity / Salinity 0.001 µS/cm to 2 S/cm 24 Vcc (4 Wires) Panel, 2" Tube or Flat Surface - 1 x 4 to 20 mA 2 contacts NO (1A/250 Vac) Alarm / ON-OFF / PWM
Conductivity Analyzer / Transmitter / Controller Conductivity / Resistivity / Salinity 0.001 µS/cm to 2 S/cm 24 Vdc (4 Wires) 2" Tube or Flat Surface Ex db ia IIC T6 Gb (optional) 2 x 4 to 20 mA 2 contacts NO (1A/250 Vac) Alarm / ON-OFF / PWM
Conductivity Analyzer / Transmitter / Controller Conductivity / Resistivity 0.01 µS/cm to 100 mS/cm 24 Vcc (2 Wires) 2" Tube or Flat Surface Ex ia IIC T6 Gb (Optional) 1 x 4 to 20 mA - -
Electrodeless Conductivity Analyzer Conductivity / Concentration 5 mS/cm to 2 S/cm 90 to 240 Vac / 50 - 60 Hz (4 Wires) Panel, 2" Tube or Flat Surface - 1 x 4 to 20 mA 1 contact NO (1A/250 Vac) Alarm / ON-OFF / PWM